Code Block |
---|
request: POST https://api.vsee.io/vc/dev/api_v3/users/905/devices headers: { "X-AccountCode" =: chroniccare360;, "X-ApiKey": = 904520ec0f12c77932bb6d0f25791131;, "X-ApiToken": = b74078949cb62a0cc2c59ba8d7362728; } parameters: { "device_id" =: "004D320DCAA2";, "device_name": = "Thermometer PT3SBT";, "type" =: "ihealth_thermometer_pt3sbt"; } |
Data Table | |||
---|---|---|---|
Data | Data Type | Unit | Unit value |
Temperature | temperature_body | temperature_unit | cel | fah |
Blood Glucose | bg | bg_unit | mg/dL | mmol/L |
Blood Pressure | hp, lp | bp_unit | mmHg | kPa |
Weight | weight | weight_unit | lbs | kg |
Active Minutes | active_minutes | ||
Steps | steps | ||
Pulse | hr | ||
Blood Oxygen | bo |
...
Code Block |
---|
request: POST https://api.vsee.io/vc/latest/api_v3/health headers: { "X-AccountCode" =: chroniccare360;, "X-ApiKey" =: 904520ec0f12c77932bb6d0f25791131;, "X-ApiToken" =: b74078949cb62a0cc2c59ba8d7362728; } parameters: { "type" =: "ihealth_thermometer_pt3sbt";, "date": = "2021-08-25";, "device_id": = "004D320DCAA2";, "data_type": = "temperature_body";, "temperature_body": = "36.76";, "temperature_unit": = "cel"; } |
parameters for blood glucose
Code Block |
---|
"data_type" = "bg", "bg" = 100, "bg_unit" = "mg/dL" |
parameters for blood pressure
Code Block |
---|
"data_type" = "bp", "hp" = 100, "lp" = 90, "bp_unit" = "mmHg" |
parameters for weight
Code Block |
---|
"data_type" = "weight", "weight" = 100, "weight_unit" = "lbs" |
parameters for active minutes & steps
Code Block |
---|
"data_type" = "active_minutes", "active_minutes" = 100, "steps" = 1000 |
parameters for pulse & blood oxygen
Code Block |
---|
"data_type" = "hr", "hr" = 100, "bo" = 100 |